Description
Cable marker label
Cable marker label, Card, white (RAL 9010), unmarked, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, THERMOMARK PRIME, THERMOMARK CARD 2.0, THERMOMARK CARD, THERMOMARK PRIME 2.0, cable diameter range: 6.1 … 14 mm, mounting type: adhesive, cable diameter: ≤ 14 mm, Number of individual labels: 8, text field height: 19 mm, text field width: 25 mm
Product properties
| Product type |
Conductor marker |
| Marking |
| Number of individual labels |
8 |
| Number of individual labels per row |
4 |
| Identification technology |
Thermal transfer |
Dimensions
| Width |
25 mm |
| Height |
19 mm |
| Depth |
0.1 mm |
| Text field |
| Text field width |
25 mm |
| Text field height |
19 mm |
Material specifications
| Adhesive |
Acrylic |
| Color |
white (RAL 9010) |
| Base element material |
PVC |
| Components |
Silicone-free |
Cable/line
| External cable diameter |
≤ 14.00 mm |
| External cable diameter |
6.1 mm … 14 mm |
Environmental and real-life conditions
| Ambient conditions |
| Ambient temperature (operation) |
-40 °C … 80 °C |
| Recommended ambient temperature (storage/transport) |
23 °C |
| Recommended humidity (storage/transport) |
50 % |
| Test for substances that would hinder coating with paint or varnish |
| Testing for paint wetting impairment substances (LABS-conformity) |
VDMA 24364-A1-L:2018-05 |
| Result |
Test passed |
| Scratch resistance |
| Specification |
EN ISO 1518-1:2023 (following) |
| Requirements |
≥ 5 N |
| Result |
Test passed |
| Tesafilm test |
| Specification |
DIN EN ISO 2409:2020-12 (following) |
| Result |
Test passed |
| UV resistance |
| Specification |
DIN EN ISO 4892-2:2021-11 (following) |
| Result |
Test passed |
| Test duration |
96 h |
| Procedure |
Artificial irradiation. |
| Temperature resistance |
| Specification |
ANSI/UL 969-2018:03 (following) |
| Test duration |
240 h |
| Rating 100 °C (121 °C) |
Test passed |
| Wipe resistance of inscriptions |
| Specification |
DIN EN 61010-1 (VDE 0411-01):2020-03 |
| Specification |
DIN EN 62208 (VDE 0660-511):2012-06 (in parts) |
| Isopropanol (99%) [67-63-0] |
Test passed |
| <i>n</i>-Hexane<br/>[CAS No. 110-54-3] |
Test passed |
| Water + Petroleum ether<br/>[CAS No. 64742-82-1] |
Test passed |
| Sodium hydroxide 0.1 mol/l<br/>[CAS No. 1310-73-2] |
Test passed |
| Ethanol (99 %)<br/>[CAS No. 64-17-5] |
Test passed |
| Acetone (99 %)<br/>[CAS No. 67-64-1] |
Test passed |
| Immersion in chemicals, oil & fuel |
| Specification |
ISO 175:2010 (following) |
| Test duration |
168 h |
| Sodium hydroxide 0.1 mol/l<br/>[CAS No. 1310-73-2] |
Test passed |
| Saltwater (saturated 350 g/l)<br/>[CAS No. – ] |
Test passed |
| Diesel<br/>[CAS No. 68476-34-6] |
Test passed |
| IRM 901 |
Test passed |
| IRM 902 |
Test passed |
| IRM 903 |
Test passed |
| Testing in a condensation changing climate in the presence of sulfur dioxide |
| Specification |
DIN EN ISO 22479:2022-08 |
| Result |
Test passed |
| Procedure |
Method B |
| Cycles |
2 |
| Salt spray test |
| Specification |
DIN EN IEC 60068-2-11 (VDE 0468-2-11):2022-10 |
| Result |
Test passed |
| Test duration |
96 h |
Mounting
📄 Download Datasheet (PDF)